Field of application
Useful for fixing any tiles (including size 60x60cm) with water absorption less than 1%, including tiles from natural stone (size 30x30 and thickness to 1 cm), porcelain tile (size 40x40 cm and thickness to 1 cm) and others on undeformable brick and concrete bases inside and outside of buildings. It can be used for coating of floors with water heating. Also, a mixture is suitable for coating surfaces without removing the old tiles (excluding glazed). The mixture is used for wall, floor cladding. Can be used as a leveling layer, can also be used for wall caps, terraces and balconies.
Mixing of mortar
Dry mixture shut with pure water (water temperature from +15°С to 20°С) at the rate of 4.75-5.25 liters of water for 25 kg of mixture, then mix up for uniformly consistence without lumps with a help of speed-low drill with nozzle or mixer. Mortar mix hold for 3-5 minutes and then it is necessary to mix it up. Finished mortar mix useful life is at least 1 hour.
Work performance
Prepared mixture is applied on a facing surface with a help of paddle, float or filling knife or align by serrated spatula. Tiles are placed on applied mixture and then pressed on. Layer thickness under tile must be 2-10 mm. Spatula teeth must coincide with the size of tile (for example, the width and depth of teeth for tile with size 15x15 cm are 6 mm, the width and depth of teeth for tile with size 40x40 cm are 12 mm ). Tiles shouldn’t be wet preliminary. Joint recommended width between tiles is no less than 2 mm. Tiles must be placed no later than 20 minutes after putting mortar mix on base. Tile position can be removed during 10 minutes after placing. Rejoining must be made no earlier than 24 hours.
Work conditions
Works should be done when the temperature of bases is from 5°С to +30°С, the air temperature is +20°С and degree of air saturation is 60%. Under other working condition technological characteristics of mixture can change. Special adhesive. It holds good moderate tiles.
Technical characteristics
Ц.1.ЗК2 ДСТУ Б В.2.7-126:2011
Structure: Cement, mineral fillers, chemical admixture
|
Discharge on 25 kg of dry mix
|
4,75 – 5,25 l
|
Thickness of applied layer
|
4 -12 mm
|
Possible technical moving time
|
at most 48 hours
|
Mortar mix useful life
|
at least 1 hour
|
Open time
|
at least 20 min
|
Correction time
|
at least 10 min
|
Tile shift
|
at most 0,5 mm
|
The strength of adhesion to the base after storage in dry air conditions
|
at least 0,8 MPa
|
The strength of adhesion to the base after watering
|
at least 0,5 MPa
|
The strength of adhesion to the base after alternate freezing and thawing, 50 circles
|
at least 0,5 MPa
|
The strength of adhesion to the basis after temperature impact
|
at least 0,5 MPa
|
Base temperature
|
from +5°С to +30°С
|
Service temperature
|
from -30°С to +70*С
|
Discharge for 1 m² with the layer thickness 1 mm calculated using dry mixture
|
apr. 1,32 kg
|