Field of application
Suitable for fixing all the tiles, including glass tiles, tiles made of artificial and natural stone, ceramic granite deformed at brick and concrete bases inside and outside buildings. Also, a mixture suitable for coating surfaces without removing the old tiles. The mixture is used for wall and floor cladding. It is effective in slabs placement of large sizes (60x60 and more). Can be used as a leveling layer.
Mixing of mortar
Dry mixture shut with pure water (water temperature from +15°С to 20°С) at the rate of 4,5-5 liters of water for 25 kg of mixture, then mix up for uniformly consistence without lumps with a help of speed-low drill with nozzle or mixer. Mortar mix hold for 3-5 minutes and then it is necessary to mix it up. Finished mortar mix useful life is at least 1 hour.
Work performance
Prepared mixture is applied on a facing surface with a help of paddle, float or filling knife or align by serrated spatula. Tiles are placed on applied mixture and then pressed on. Layer thickness under tile must be 4-10 mm. Spatula teeth must coincide with the size of tile (for example, the width and depth of teeth for tile with size 15x15 cm are 6 mm, for tile with size 30x30 cm is 10 cm). Tiles shouldn’t be wet preliminary. Joint recommended width between tiles is no less than 2 mm. Tiles must be placed no later than 20 minutes after putting mortar mix on base. Tile position can be removed during 10 minutes after placing. Rejoining must be made no earlier than 24 hours.
Work conditions
Works should be done when the temperature of base is from 5°С to +30°С, the air temperature is +20°С and relative humidity is 60%. Under other working condition technological characteristics of mixture can change.
Unique adhesive is used for works with deformable surfaces. Increased thermal stability (up to 70 ° C), and water resistance. Suitable for decorating fireplaces, swimming pools and under floor heating (including water and electric heating). Suitable for lining wooden bases (including QSB and OSB boards) as well as to lay the old tiles with glaze.
Technical characteristics
Ц.1.ЗК4 ДСТУ Б В.2.7-126:2011
Structure: Cement, mineral fillers, modifier additives of leading manufacturers
|
Discharge for 25 kg of dry mix
|
4,5 – 5,0 l
|
Thickness of applied layer
|
4 -10 mm
|
Possible technical moving time
|
at most 48 hours
|
Mortar mix useful life
|
at least 1 hour
|
Open time
|
at least 20 min
|
Correction time
|
at least 10 min
|
Tile shift
|
at most 0,5 mm
|
The strength of adhesion to the base after storage in dry air conditions
|
at least 1 MPa
|
Base temperature
|
from +5°С to +30°С
|
Service temperature
|
from -30°С to +70*С
|
Discharge for 1 m² with the layer thickness 1 mm calculated using dry mixture
|
apr. 1,2 kg
|